The Way to Best LCOE (IV)

Trina Solar Co., Ltd

PR91742

 

CHANGZHOU, China, Sept. 17, 2021 /PRNewswire=KYODO JBN/ --

 

- Fraunhofer ISE study I: Vertex 670W's LCOE reduced by 7.4%, Trina Solar 210

mono-facial modules with fixed tilts demonstrate outstanding system value

 

Recently, Fraunhofer ISE, the world leading solar institution, has completed

the assessment of CAPEX and LCOE of new generation of ultra-high power modules

210mm (G12) from Trina Solar and 182mm (M10) series from other manufacturer.

 

Founded in 1981, Fraunhofer ISE is the largest solar research institute in

Europe. Based in Freiburg, Germany, it is a constituent entity of

Fraunhofer-Gesellschaft, the world's leading applied research organization.

 

The study results show that the new generation of 210mm (G12) and 182mm (M10)

modules performs better than the conventional 166mms (M6) modules in both CAPEX

and LCOE, G12 performs better than M10, and M10 performs better than M6. The

CAPEX of the Vertex G12 670W is 4.2% lower than that of the M10 540W modules,

and the LCOE is 4.1% lower than the latter. The LCOE of the Vertex G12 670W is

4.5% lower than that of the M10 585W modules, and is up to 7.4% lower than that

of the M6 455W modules.

 

Results:

 

1.  The Vertex G12 modules have the best CAPEX and LCOE. Compared to the M10

modules, the G12 600W and 670W modules perform particularly well, reducing

CAPEX by up to 1.5-2 EURcWp and LCOE by up to 3-4.5%. Compared to the M6

modules, the LCOE could be reduced by 6.5%-7.4%.

 

2.  Due to savings on the fixed-tilt mounting system, G12 600W and 670W modules

possess savings of around 0.5~1 EURcWp or 11% compared to the M10 series.

 

3.  Thanks to the innovative design of low-voltage and high-string power, the

210mm 550W, 600W and 670W modules have savings of the costs of electrical

systems, which are up to approximately 14.1~21.4% compared to the M6 series.

 

4.  Lower transportation costs account for the superior performance of the G12

600W and 670W modules. Within the same 40-foot container, the power of loadable

G12 600W and 670W modules can be increased by about 12%.

 

In the era of grid parity, the advanced Vertex 210mm series of modules have a

prominent edge in Levelized Cost of Energy (LCOE).

 

Assessment site: Germany

 

Method of installation: Fixed-tilts (landscape)

 

Inverter: string inverter

 

Module Power [W] 455 540 550 590 605 665
Cell Type M6 M10 G12 M10 G12 G12
Module Size [mm] 2102 x 1040 2256 x 1133 2384 x 1096 2411 x 1134 2172 x 1303 2384 x 1303







Inverter SUN2000-215KTL-H0 / SUN2000-215KTL-H3
Modules/String 28 28 37 26 34 31
Strings/Inverter 19 16 12 16 12 12
String power [kW] 12.74 15.12 20.35 15.34 20.57 20.62







DC/AC Ratio 1.14 1.13 1.15 1.14 1.15 1.15
Pitch [m] 6.03 6.56 6.35 6.56 7.53 7.53
Tilt [°] 20°
Shading angle [°] 35°
GCR 54.8%







DC Capacity [kW] 9,924 9,919 10,012 10,063 10,120 10,143
AC Capacity [kW] 8,815
Module numbers 21,812 18,368 18,204 17,056 16,728 15,252
Inverter numbers 41








Figure IV: Assessment parameters

 

Click to download Fraunhofer ISE's PPTs on the Vertex modules tests:

 

https://pages.trinasolar.com/GLB-PV-tech.html

 

Three rounds of assessment of Trina Solar's Vertex series by DNV GL, a leading

international third-party organization.

 

The Way to Best LCOE (I)

 

https://mgr.trinasolar.com/en-glb/resources/newsroom/mathe-way-best-lcoe-i-%E2%80%93-system-value-assessment-trina-600w-vertex-bifacial-dual

 

 

The Way to Best LCOE (II)

 

https://mgr.trinasolar.com/en-glb/resources/newsroom/mathe-way-best-lcoe-ii

 

The Way to Best LCOE (III)

 

https://mgr.trinasolar.com/en-glb/resources/newsroom/mabos-costs-reduced-63-dnv-gl-report-trina-solar-vertex-210mm-modules%E2%80%99-advantages

 

 

For more information, please contact Trina Solar's local sales representatives.

Or Mailto: VertexValue@Trinasolar.com

 

SOURCE  Trina Solar Co., Ltd

 

Image Attachments Links:

 

   Link: http://asianetnews.net/view-attachment?attach-id=401034

 

   Caption: Figure I: Calculation results of CAPEX

 

   Link: http://asianetnews.net/view-attachment?attach-id=401036

 

   Caption: Figure II: Calculation results of LCOE

 

   Link: http://asianetnews.net/view-attachment?attach-id=401037

 

   Caption: Figure III: Comparison of items of CAPEX research results

 

 

本プレスリリースは発表元が入力した原稿をそのまま掲載しております。また、プレスリリースへのお問い合わせは発表元に直接お願いいたします。

このプレスリリースには、報道機関向けの情報があります。

プレス会員登録を行うと、広報担当者の連絡先や、イベント・記者会見の情報など、報道機関だけに公開する情報が閲覧できるようになります。

プレスリリース受信に関するご案内

SNSでも最新のプレスリリース情報をいち早く配信中